Mouse Serology Panel

The Mouse Serology Panel is a diagnostic tool designed to detect antibodies against five significant pathogens affecting mice: Mouse Hepatitis Virus (MHV), Mouse Parvovirus (MPV), Minute Virus of Mice (MVM), Theiler’s Murine Encephalomyelitis Virus (TMEV), and Rotavirus. This panel utilizes advanced indirect fluorescent antibody (IFA), ensuring precise identification of exposure to these infectious agents.

2 ml Serum

  • Collect an adequate amount of blood in a plain red-top tube or serum separator tube (yellow-top tube). Allow it to clot at room temperature for 30 to 60 minutes before separation.

  • Centrifuge to separate the serum. Transfer the clear serum into a new, leak-proof plain red-top tube and label it as "serum."

  • Excessively hemolyzed samples are not suitable for this test.

  • Unspun samples will not be accepted.

  • Refrigerate sample at 4oC until shipment.

  • Label each sample with the animal’s name and a unique identifier, using a permanent marker or a secure adhesive label

  • Ensure the submittal form is completed with the animal’s information and relevant medical history.

  1. Fox, J. G., et al. (2023). Laboratory Animal Medicine, 4th Edition. Academic Press.

  2. Bhatt, P. N., et al. (2022). "Serological detection of viral infections in laboratory mice." Journal of Comparative Pathology, 191(1), 12-24.

  3. Smith, A. L., et al. (2022). "Impact of murine viral infections on research outcomes: A focus on MHV, MPV, and MVM." Veterinary Pathology, 59(3), 345-357.

  4. Harkness, J. E., & Wagner, J. E. (2023). The Biology and Medicine of Laboratory Rodents and Rabbits, 6th Edition. Wiley-Blackwell.

  5. Schoondermark-Van de Ven, E. M., et al. (2023). "Comprehensive serological screening for viral infections in laboratory mice." Journal of Veterinary Diagnostic Investigation, 35(5), 456-465.

Test Code
A114
Section
Avian & Exotics Immunodiagnostics
Species
Mouse
Turnaround Time
Contact Vettto Team
Specimen
Collection Guidelines
Packaging Instructions
References